We supply breakers of every class for villas, towers, hotels and industrial sites, from miniature breakers for final circuits up to air circuit breakers for main switchboards, plus residual-current devices for personal protection. Send your load schedule or bill of quantities and we will propose the right rating and breaking capacity.

Items we supply

Pick and add to your list

Press “Add” to put an item on your quote list, then send the whole list on WhatsApp.

  1. 01 Miniature circuit breakers (MCB)
  2. 02 Moulded-case breakers (MCCB)
  3. 03 Air circuit breakers (ACB)
  4. 04 Residual-current devices (RCCB / RCBO)
  5. 05 Breaker accessories and busbars

Specific item

A specific item

View quote list

Technical guide

Breaker types by current rating

The breaker type follows from the rated current and its place in the system: miniature breakers for final circuits, moulded-case breakers for feeders and sub-main boards, and air circuit breakers for main switchboard incomers.

Common current ranges
TypeCommon rangeTypical use
MCB6 – 63 ALighting, socket and AC circuits
RCCB / RCBO25 – 100 A · 30 / 100 / 300 mAProtection of people against earth leakage
MCCB16 – 1600 ASub-main feeders and board incomers
ACB630–800 A and aboveMain incomers of MDBs
Ranges vary by manufacturer and model.

MCCBs: when you need one

A moulded-case circuit breaker (MCCB) is used when the current is above the MCB range or when you need higher breaking capacity and adjustable trip settings. It is usually the incomer of an SMDB and the outgoing breaker in an MDB.

  • Frame size and rated current (In).
  • Number of poles: 3 or 4.
  • Trip unit: thermal-magnetic or electronic.
  • Breaking capacity (Icu) in kA to suit the fault level.

Residual-current devices: RCCB and RCBO

A residual-current circuit breaker (RCCB) disconnects a circuit when it detects current leaking to earth; 30 mA sensitivity is the usual choice for personal protection in bathrooms, kitchens and outdoor sockets. An RCBO combines earth-leakage protection with overload and short-circuit protection in one device.

Sensitivity and use
SensitivityTypical use
30 mAPersonal protection: bathrooms, kitchens, outdoor sockets
100 mAProtection of circuit groups
300 mAFire protection at board level

Breaking capacity (kA) explained

Breaking capacity is the highest short-circuit current a breaker can interrupt safely, given in kiloamps (kA). It must be at least the prospective fault current where the breaker is installed. MCBs are commonly 6 kA or 10 kA; MCCBs start around 16 kA and go higher by model.

On MCBs you see Icn (IEC 60898-1); on MCCBs you see Icu and Ics (IEC 60947-2). Ics is the level after which the breaker remains fit for normal service.

Trip curves B, C and D

MCB trip curves
CurveMagnetic tripUse
B3 – 5 × InResistive loads: lighting and heaters
C5 – 10 × InGeneral use: sockets, AC units, small motors
D10 – 20 × InHigh inrush: transformers, pumps, large motors
In is the rated current of the breaker.

Brands

Brands available in this category

  • Schneider Electric
  • CHINT
  • General Electric
  • Hyundai
  • Legrand

Questions

Common questions

Which brands do you supply for Circuit breakers?

We supply Circuit breakers from brands including Schneider Electric, CHINT, General Electric, Hyundai, Legrand, and propose consultant-approved alternatives when needed.

How do I get a price for Circuit breakers?

Add items to your quote list from this page or send the specification and quantity on WhatsApp at +966 55 573 8438. We reply to quote requests the same working day.

WhatsApp Quote list